6WDUWLQJXS
L7XUQRQWKHZDWHUVXSSO\WDS)LJ
L7XUQWKHPDLQVZLWFKWKHSXPSLVDFWLYDWHG¿OOLQJ
the boiler.
L When the water reaches the correct level, the pump
stops.
Turn the main switch 2 to begin heating the water
in the boiler then turn each one until water begins
WRÀRZIURPWKHP
L Wait for the machine to reach its working pressure
and to reach the correct thermal balance.
0RGHOVZLWKJDV(Fig.8)
L 7XUQRQWKHZDWHUVXSSO\WDS)LJ
L Turn on the gas tap 3 (Fig.6).
L 7XUQWKHPDLQVZLWFKWKHSXPSLVDFWLYDWHG¿OOLQJ
the boiler.
L When the correct level is reached, the pump stops.
Turn the switch 2.
L Turn the gas tap 10 to the vertical open position
and hold down the incorporated button, at the same
WLPHUHSHDWHGO\SUHVVKDUGRQWKHSLH]HOHFWULFEXW-
WRQXQWLOWKHVSDUNOLJKWVWKHJDVÀDPHFDUU\RXW
this operation looking through window 14). Hold
the tap button 10 down for approx. 30 seconds to
DOORZWKHVDIHW\V\VWHPWRNHHSWKHÀDPHOLJKWHG
,IWKHÀDPHJRHVRXWUHSHDWWKHRSHUDWLRQ
6KRXOGWKHÀDPHQRWOLJKWXSDYRLGLQVLVWLQJ
and close the gas tap by turning it 90° in a
FORFNZLVHGLUHFWLRQ
L Wait until the machine reaches its working pressure
and until the correct thermal balance is achieved.
)RDPHGPLON
Press the button to excite the steam and emulsion
GHOLYHU\HOHFWURPDJQHWLFYDOYHVXQWLOWKHSURJUDP-
med temperature and froth level are reached or
until the function is switched off.
6WHDPHGPLON
3UHVVLQJ WKH NH\ H[FLWHV WKH VWHDP GLVWULEXWLRQ
electro-valves until the programmed temperature
is reached or until the same is pressed again.
6DIHW\'HYLFHV
Dispensing cannot be carried out if the machine
has not reached the operating pressure or tempe-
rature at least once, and each time that the boiler
pressure drops too much.
 6WHDPVXSSO\KDQGZKHHO³&/(9(5´
5RWDWLQJWKHWXUQNQREXSZDUGVZLOORSHQWKHWDS
the turn-knob will remain in open position to allow
IRUDFRQWLQXRXVVWHDPVXSSO\7RFORVHWKHWDS
turn the turn-knob back into its horizontal position.
Rotating the turn-knob downwards provides for
LQVWDQWVWHDPVXSSO\2QFHLWLVUHOHDVHGWKHWXUQ
knob will go back into its horizontal position and
WKHVWHDPVXSSO\LVLQVWDQWO\VWRSSHG
 6XSSOHPHQWDU\PDQXDOZDWHU¿OOLQJWDSSRVL-
WLRQHGXQGHUWKHGLVFKDUJHEDVLQ
3UHVVGRZQWR¿OOWKHERLOHU
9DOYHGJDVSRZHUWDS (models with gas heating).
Open: vertical position;
&ORVHGWXUQLQFORFNZLVHGLUHFWLRQ
3LH]RHOHFWULFEXWWRQ (models with gas heating).
)LULQJ EXWWRQ SUHVV GRZQ ¿UPO\ WR JLYH RII WKH
VSDUNWROLJKWWKHJDVIRUWKHEXUQHU
&RQWUROLQVWUXPHQWV (Fig.8)
12 GaugeZLWKPRELOHQHHGOHRQD¿[HGGLDOZLWKD
double scale.
Visual control of the pump (manometer on the left-
hand side) and of the boiler pressure (manometer
on the right-hand side)
13 Minimum and maximum water OHYHOLQGLFDWRU
9LVXDOFRQWURORIZDWHUOHYHOLQERLOHU
&RQWUROZLQGRZ(models with gas heating).
Visual control of lighting and functioning of the
ÀDPHRIWKHJDVEXUQHU