9. ADJUSTMENT AND SETTING OF THE
DOSE
9.1. Models DE
It is possible to adjust the dose of coffee and hot water
dispensed by electronically controlled models. (If the
function is enabled)
9.1.1. Adjusting the dose
The quantity of coffee and hot water dispensed can
be adjusted using the button panel or the hot water
controls.
1 Press the button E on any button panel and hold
it down for 8-10 seconds until water stops flowing
from the dispensing unit and the led of the conti-
nuons button on the first button panel on the left
begins flashing.
2 It is necessary to act as to make 1 or 2 cups in or-
der to reach the correct coffee amount adjustment
in the cup.
3 Put the filter-holder (with ground coffee) on the left
unit and the cup under the spout.
4 Operate the selected button (i.e. button A for one
small cup).
5 One the required coffee amount in the cup has
been reached, press the stop button A. Coffe will
stop pouring and the microprocessor will store the
dose.
6 Press the continuous button E again; the led will go
out and the machine will store the new quantity.
7 Make the coffee and check the cup amount in order
to check that programming is correct.
If some doses have to be changed (A-B-C-D), once
at point 5 repeat the instructions in points 3-4-5 for
each dose, remembering to use the filter-holder with
relevant filter and freshly ground coffee.
Then carry out point 6 and repeat point 7 to check
all changed doses.
If all units are to be programmed with the same doses,
the selection of coffee doses is finished. If the dosage
of another unit is to be changed (1-2-3-4 doses), pro-
ceed as indicated in the above-mentioned point 1-7,
using only the button panel of the selected unit.
9.1.2. Adjusting the quantity of hot water
Proceed as follows:
1 Press the continuous E button on any button panel
and hold down for 8-10 seconds until water stops
flowing from the dispensing unit and the led of the
E button on the first button panel on the left starts
flishing. The machine is ready to accept quantity
variations.
2 Put a cup or a jug to receive the water under the
water spout 15 (Fig.3).
3 Push the delivery button 5B
4 Once the required amount is reached, press the
button 5b again. Water will stop pouring and the
microprocessor will store the dose.
- To adjust the water dose for the dispensing spout
12 (Fig. 3), proceed in the same way using button
5b.
5 Once adjusted, press the stop-continuous button
E on any button panel; the led will go out and the
machine will store the new quantity.
6 Pour out doses of hot water to check that program-
ming is correct.
WARNING!
The amount of hot water dispensed can be controlled
by proceeding as follows:
press the hot water control button 5A and hold
down for at least 2 seconds; when the button is relea-
sed, the machine will dispense water continuously.;
to manually stop dispensing, press the water con-
trol button 5A again when the required amount has
been dispensed.
To stop dispensing the measured amounts of hot
water, press the water control button 5A.
9.2. Tray position adjustment (Fig.14-15-16-
17-18-19-20)
The machine is supplied with tray fixed in high po-
sition.
However the tray can be placed in a lower position to
allow the introduction of high cups or pots.
To carry out this operation, proceed as follows:
- Remove the cup holding grids and the liquid col-
lection tray.
- Unscrew the 4 screws (2 right - 2 left) as shown in
Fig.14 and remove the whole group.
- Unscrew the lower front case (fig.15)
- Unscrew the two fixing screws of the square sup-
porting the exhaust tank (Fig.16).
- Detach the silicone tube and remove the lower
exhaust pipe.
- Turn the basin upside down and using a fixed
wrench (32 mm) loosen the nut and remove the
square (Fig.17).
- Re-assemble the tank by fixing it with the nut in
the hole expressly made in the bottom plate.
Re-assemble the silicone tube and the lower
exhaust pipe (Fig.18).
- Place the lower front case above as shown in
Fig.19.
- Fix the tray group in the place of the lower case
(Fig.20) and install the liquid collection tray and
the cup holding grid.